TRANSASIA · Model ERBA XL-300
• Unique result re-calculation facility that eliminates repeat runs • Allows to use Immuno Turbidimetric, Latex Turbidimetric based methods • Static photometer design with diffraction grating and diode array detectors • Lower reagent consumption due to reading volume of 200 µ • Unlimited test programmes, any number of calculation items,unlimited test profiles • Choice of 12 wavelengths from 340 to 750 nm with O.D. range from 0 to 3.5 Abs • Quality Control programme to provide daily & monthly Levy-Jenning Graphs & Twin Plot • Soft start and stop of all reagent and sample probes • Vertical Obstruction Detection (VOD) system protects the probe needles from damage • Separation of biohazardous waste for safe disposal • Float sensor based platform with alarms for D.I. water, cleaning solution and waste containers • Storage of calibration trace data with reagent blank O.D. and calibration O.D.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.