Swelab · Model AC-Series
All parameters and histograms (RBC, WBC, PLT) showed on display and print-out. Memory of 800 control results, and 600 samples including histograms. Levey-Jennings plots and X-bar calculations. No start-up time and automatic stand-by position. Built in dilutor–only one manual step has to be performed. Case Book with over 80 examples of hematological diseases, physological changes and artefacts AutoCounter (AC), compared with the microscopic blood smears. Reagent level detectors. Printer output and serial output as standard.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Flagged or implausible CBC counts, clog alarm, poor precision.
Root cause: Debris or a clot partially blocking the counting aperture.
Symptoms: WBC / HGB results shifted, high background, reagent-empty or pressure alarms.
Root cause: Reagent pack depleted or expired, or a valve / tubing fault.
Symptoms: Short samples, no aspiration, probe-position errors.
Root cause: Worn or bent sample probe, or a clot in the sample.
Symptoms: Haemoglobin results biased, blank absorbance off.
Root cause: Photometer lamp aging or a dirty flow cell.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample probe | Periodic replacement | $$ | Moderate |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
| Reagent / diluent pack | Consumable | $$ | Easy |
| HGB photometer lamp / flow cell | Periodic replacement | $$ | Moderate |
| Aperture assembly | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.