Sysmex · Model XP-300
Accurate and reliable Proven technology for accuracy of results Linearity to support clinical diagnostics and monitoring Sensitive flagging to support diagnosis by the physician Performs rapid and accurate analysis of a 17-parameter CBC Including a 3-part WBC differential with an Absolute Neutrophil Count Histograms for RBC, WBC and PLT Automatic floating discriminators Produces accurate results comparable to other Sysmex hematology analyzers Small footprint Fits easily on a laboratory bench Ideal as a back-up for Sysmex X-Series™ and XN-Series™ analyzers Minimal training required Barcoded QC and reagents Auto start-up and shut-down Safe and secure Non-toxic, biodegradable reagent system Two reagents (diluent and lyse) for complete results Data transfer to LIS via LAN (TCP/IP) or Serial Port (RS-232C) Bi-directional interface Same direct current detection method as Sysmex high-end systems to provide accurate, comparable results Minimal training required Simple menus Push button technology Non-toxic, biodegradable reagents Reliable hardware and results Network capability via your LIS
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.