Pointe Scientific · Model 180-PLUS
• BICHROMATIC PHOTOMETER SYSTEM - Differential wavelengths to correct for test tube imperfections and to help remove interfering substances. • ON-BOARD INCUBATOR - 12 wells at 37° C. • TEMPERATURE CONTROLLED CUVETTE WELL - Constant 37° C. This feature is necessary for performing kinetic assays. • INTERNAL TEMPERATURE CONTROL - The analyzer monitors the incubator and cuvette well temperatures. The temperatures are automatically corrected and the actual temperature in degrees (°C) is displayed on the screen. • LAMP SAVING FEATURE - The instrument automatically shuts off the lamp if the instrument has not been used for 15 minutes. This feature can preserve the lamp for up to two (2) years, depending on actual usage. • MAINTENANCE FREE - The instrument does not require any scheduled maintenance procedures. • SELF-PROMOTING OPERATION - The analyzer leads the user through test performance in a step-by-step manner. • TEST TUBE ACTIVATED READING - The analyzer reads test tubes upon insertion-no need to press a button. • FAST READOUT - The analyzer reads, calculates and prints results in under three (3) seconds. • PREPROGRAMMED CHEMISTRY PROCEDURES - Optimized parameters for Pointe Scientific reagents are already entered-just select the test number. Open channels are available for programming other tests. • PREPROGRAMMED DATA REDUCTION - Calculation programs for cardiac risk factors, Glycohemoglobins and Iron/TIBC are part of the general test menu. • PREPROGRAMMED NORMAL RANGES - The analyzer prints the normal ranges and can be edited to fit the area or population. • PREPROGRAMMED FLAGS - The analyzer will flag results that are out of the normal range or exceed the linear limits of the analyzer or reagents. • AUTOMATIC WAVELENGTH SELECTOR - The analyzer automatically positions the preselected filters for each test. The inclusion of the 340nm filter enables the analyzer to perform assays in the ultra-violet (UV) mode, which is the preferred mode for enzyme/kinetic, assays.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.