Pointe Scientific · Model 180-PLUS
BICHROMATIC PHOTOMETER SYSTEM - Differential wavelengths to correct for test tube imperfections and to help remove interfering substances. ON-BOARD INCUBATOR - 12 wells at 37° C. TEMPERATURE CONTROLLED CUVETTE WELL - Constant 37° C. This feature is necessary for performing kinetic assays. INTERNAL TEMPERATURE CONTROL - The analyzer monitors the incubator and cuvette well temperatures. The temperatures are automatically corrected and the actual temperature in degrees (°C) is displayed on the screen. LAMP SAVING FEATURE - The instrument automatically shuts off the lamp if the instrument has not been used for 15 minutes. This feature can preserve the lamp for up to two (2) years, depending on actual usage. MAINTENANCE FREE - The instrument does not require any scheduled maintenance procedures. SELF-PROMOTING OPERATION - The analyzer leads the user through test performance in a step-by-step manner. TEST TUBE ACTIVATED READING - The analyzer reads test tubes upon insertion-no need to press a button. FAST READOUT - The analyzer reads, calculates and prints results in under three (3) seconds. PREPROGRAMMED CHEMISTRY PROCEDURES - Optimized parameters for Pointe Scientific reagents are already entered-just select the test number. Open channels are available for programming other tests. PREPROGRAMMED DATA REDUCTION - Calculation programs for cardiac risk factors, Glycohemoglobins and Iron/TIBC are part of the general test menu. PREPROGRAMMED NORMAL RANGES - The analyzer prints the normal ranges and can be edited to fit the area or population. PREPROGRAMMED FLAGS - The analyzer will flag results that are out of the normal range or exceed the linear limits of the analyzer or reagents. AUTOMATIC WAVELENGTH SELECTOR - The analyzer automatically positions the preselected filters for each test. The inclusion of the 340nm filter enables the analyzer to perform assays in the ultra-violet (UV) mode, which is the preferred mode for enzyme/kinetic, assays.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results, drift over a shift.
Root cause: Reagent or cuvette issue, lamp ageing, a probe / mixer / wash-station fault, or ISE-module problems.
Symptoms: Short aspiration, no dispense, clot detection, probe-position error.
Root cause: Clogged or bent probe, or a clot in the sample.
Symptoms: High cuvette blanks, non-uniform results by position, rotor-drive error.
Root cause: Worn / scratched cuvettes or a wash fault, or a rotor-drive fault.
Symptoms: Electrolyte results biased or noisy, ISE calibration fails.
Root cause: Aged ISE electrodes / reference, or a pinch-valve / tubing fault.
Symptoms: Multiple station alarms, priming failures, poor wash.
Root cause: Water / DI supply quality, a pump, or a vacuum / pressure regulator.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probes | Periodic replacement | $$ | Moderate |
| Photometer lamp | Frequent wear item | $$ | Moderate |
| Reaction cuvettes / segment | Frequent wear item | $$ | Easy |
| ISE electrodes (Na / K / Cl) & reference | Frequent wear item | $$ | Fairly easy |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.