Nihon Kohden · Model Celltac Alpha MEK-6500K
Built-in open and closed tube mode To reduce the risk of contamination, the Celltac α MEK-6500K includes both, an open and a closed tube mode for easy blood sampling. Auto dilution mode change You can set panic value thresholds (abnormal high and low values) to trigger re-measurement in preset dilution ratio modes (low, normal, high, higher). In higher mode the measuring range for WBC can be extended to 599 x 10³/μl while the low dilution mode gives high accuracy even in low values of WBC or PLT. Capillary mode The Celltac α MEK-6500K allows you to analyze capillary blood with only 10 μl. This is the ideal method to perform CBCs inclusive 3-part-diff for pediatric and geriatric patients. Unlimited patient memory The instrument can store unlimited patient samples together with QC results and alarm logs by using SD-card memory (2GB can store 30 000 patient samples).
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.