Mindray · Model BC-5380
Laser scatter differential to ensure outstanding accuracy Semi-conductor laser scatter to differentiate white blood cells by cell size and granule complexity Patented cluster algorithm to separate cell groups with great precision Intuitive flagging information to help determine abnormal samples Versatile automated sampling 30-tube autoloader for continuous loading · Independent closed tube compartment for STAT and capillary samples Supports selected microtainer tubes Only 20uL blood and 1min are required to get a five-part report Supports both whole blood and capillary blood samples 20uL blood sampling for CBC+DIFF tests and 15uL for CBC tests Up to 60 samples per hour throughput Economical reagent consumption User-friendly software for easy operation and maintenance Customization on reference range, report styles and auto-cleaning schedule Day-to-Day QC monitoring Bi-directional LIS connection
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.