Horiba Medical · Model LC-178 CRP
Speedy measurement of total 19 items including blood count Three-part differential of WBC Quantitative CRP simply by setting the sample to the sample holder without pretreatment The LC-178 CRP has been further improved to allow the following features: (1) Widening CRP measurement range The previous model allows the CRP measurement range in whole blood of 0.2 to 10 mg/dL (for plasma and/or serum, 0.2 to 0.7 mg/dL). LC-178 CRP dramatically improves the linearity of high concentration range due to the improved CRP reagents. The measurement range has been widened to the double, 0.2 to 20 mg/dL in whole blood, and 0.2 to 15 mg/dL for plasma and/or serum. Sample memory function With an optional card attached, the LC-175 CRP is now available to record measurement data as many as of 50 samples, and to record/calculate accuracy control data as many as of 30 samples. All of the LC-178CRP models are equipped with the card as a standard specification, allowing the flexible data management necessary for the current and future users.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →