HESKA · Model Element DC
• Now with E-Wrap! Turn the convenience of our pre-surgical and comprehensive panels into a 1-step timesaver. • Electrolytes and More: Electrolytes on one slide, pre-packaged panels (including the Comprehensive Plus), and individual slide options let you configure the profiles you require. • Whole Blood Solution: Heska’s lithium heparin sample tubes save you a step. Go from syringe to centrifuge to analyzer with no pipetting required. Sampling Flexibility: Choose the 1.5-ml heparinized sample tube, or pipette serum or plasma from your regular green-top or red-top tubes into a non-heparinized tube. • Whole Blood Solution: Heska’s lithium heparin sample tubes save you a step. Go from syringe to centrifuge to analyzer with no pipetting required. • Additional testing at the touch of a button: Add a new slide to your patient’s panel even after the analysis has begun. • Stack and Run: Load up to 22 tests (20 slides) at one time without jamming, using the convenient stackable slide rack.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →