Fujifilm · Model Dri-Chem NX500i
Simple 3-step procedureFully Automated Procedure 1 step - Set the slide (Dry Slide Reagents) 2 step - Set the sample 3 step - Press START No Parameter Input Required Information of the parameter is incorporated in the bar code printed on the back of every slide. No pre-treatment of sample required Plasma Filter (PF) can cut the turn around time and the pre-treatment process of the sample. It can generate plasma sample by aspirating and separating the whole blood inside the PF within 1 minute. Just set the PF on top of the sample tube and press START. 1. Have the PF card read in the designated analyzer. 2. Set PF on the top of sample tube. - (A) 3. Press Start. 4. Suction unit move to be connected on PF and start aspiration of whole blood.- (B) Easy operation by touch screen# 5.7 inch VGA, 640 480# Qwerty touch Key board. Basic Mode /Advanced Mode are available according to user preference. (Basic Mode: displays operation procedure for one sample only. Advanced Mode: displays operation procedure for one sample and measurement status for previous measured samples.)Only 10μL/Test# Each test needs only 10μL of sample. (CRP needs 5μL/test, ISE needs 50μL/3 tests). Manual pipetting can be also performed when less sample available. Less invasive for newborn at NICU.No calibration required* QC card system# A magnetic card called QC card will adjust the lot variability in the slide reagents.# A QC card comes with every reagent box.# The analyzer memorizes the lot adjustment information once a QC card is swiped. No need to swipe QC in every measurement for the same slide lot. Accurate and reliable test results from long term and field-proven technology & experience Minimize the risk of biological hazard
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →