Elan Diagnostics · Model ATAC 8000
Refrigerated Reagent Tray - The ATAC 8000 holds 40 individual ATAC-PAK reagents for a maximum of a 6,000 test capacity, providing over 12 hours of walk-away operation. On board refrigeration assures reagent stability and continuous inventory monitoring enables the operator to know the number of tests remaining in each PAK. Integrated ISE Module - The integrated ISE Module utilizes a proprietary, solid state, electrode design for Na, K, Cl, and CO2. No filling or pre-treatment required solution, only on demand test results as requested. High Capacity Sample Chamber - 70 positions are available for disposable micro sample cups, standard vacutainer tubes, standards, controls, and STAT samples. Cuvette Assembly: 25 cuvettes are precision matched for accuracy and reproducibility. Positioned in a peltier regulated housing, the glass cuvettes are cleaned and reused automatically. On-Board Diluent - There is no need for a separate water system. The ATAC 8000 is independent of the laboratory's water supply and has an onboard diluent tank for easy filling. An optional 20 liter carboy is available for high volume users. Sample Probe Module - The unique tapered design and automatic washing eliminates sample carryover. The reagents are pre-heated to 37C as they are delivered through the probe providing optimal reagent temperature and consistent measurements for improved performance.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Potential for reporting lower than actual HDL (cholesterol) results due to low QC Recovery
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →