Elan Diagnostics · Model ATAC 8000
Refrigerated Reagent Tray - The ATAC 8000 holds 40 individual ATAC-PAK reagents for a maximum of a 6,000 test capacity, providing over 12 hours of walk-away operation. On board refrigeration assures reagent stability and continuous inventory monitoring enables the operator to know the number of tests remaining in each PAK. Integrated ISE Module - The integrated ISE Module utilizes a proprietary, solid state, electrode design for Na, K, Cl, and CO2. No filling or pre-treatment required solution, only on demand test results as requested. High Capacity Sample Chamber - 70 positions are available for disposable micro sample cups, standard vacutainer tubes, standards, controls, and STAT samples. Cuvette Assembly: 25 cuvettes are precision matched for accuracy and reproducibility. Positioned in a peltier regulated housing, the glass cuvettes are cleaned and reused automatically. On-Board Diluent - There is no need for a separate water system. The ATAC 8000 is independent of the laboratory's water supply and has an onboard diluent tank for easy filling. An optional 20 liter carboy is available for high volume users. Sample Probe Module - The unique tapered design and automatic washing eliminates sample carryover. The reagents are pre-heated to 37C as they are delivered through the probe providing optimal reagent temperature and consistent measurements for improved performance.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results, drift over a shift.
Root cause: Reagent or cuvette issue, lamp ageing, a probe / mixer / wash-station fault, or ISE-module problems.
Symptoms: Short aspiration, no dispense, clot detection, probe-position error.
Root cause: Clogged or bent probe, or a clot in the sample.
Symptoms: High cuvette blanks, non-uniform results by position, rotor-drive error.
Root cause: Worn / scratched cuvettes or a wash fault, or a rotor-drive fault.
Symptoms: Electrolyte results biased or noisy, ISE calibration fails.
Root cause: Aged ISE electrodes / reference, or a pinch-valve / tubing fault.
Symptoms: Multiple station alarms, priming failures, poor wash.
Root cause: Water / DI supply quality, a pump, or a vacuum / pressure regulator.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probes | Periodic replacement | $$ | Moderate |
| Photometer lamp | Frequent wear item | $$ | Moderate |
| Reaction cuvettes / segment | Frequent wear item | $$ | Easy |
| ISE electrodes (Na / K / Cl) & reference | Frequent wear item | $$ | Fairly easy |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Potential for reporting lower than actual HDL (cholesterol) results due to low QC Recovery
From BioLab, for work done with this kind of equipment.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio