BioSystems · Model Analyzer A25
Throughput of 240 test/hour Clinical Chemistry ad Turbidimetry dedicated reagents 30 refrigerated positions by 20 and 50 mL reagents bottles Refrigeration system with switch independent from analyzer 3 positions without refrigeration for sample and reagent racks 24 samples per rack. Maximum capacity of 72 samples Maximum capacity of 52 reagents New dispenser arm assembly Low dead volume sample and reagent Impact detection system Recalibration automatic positioning of needle Primary tubes or pediatric cups as sample containers Unlimited STAT capabi1ities. Run at anytime Up to 15 minutes reading time Reaction volume between 200 and 800 uL Measurement Range from -0.05 A to 2.5 A Spectral range 340 at 900 mm Hard Coating Filter (340, 405, 505, 535, 560, 600, 635, 670nm) Automatic conditioning of system fluid
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.