Beckman Coulter · Model AU2700
• Standardization - Only Beckman Coulter standardizes chemistry testing from 400 to 6,600 tests per hour for low to very high volume laboratories. This translates to higher productivity, increased efficiency and greater cost savings for your lab. • Fast and Reliable Turnaround Times - Up to 1600 photometric tests per hour and up to 2133 tests per hour with electrolytes > Immediate STAT interrupt with HCFA basic metabolic eight test panel results available within five minutes • 300-sample rack loading for peak workloads • 22-sample carousel for STAT • Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric cups • Mixed bar code capability • Automated reflex and repeat testing • Automated pre-dilution for urine and other specimens • Easy connectivity for automation • Reagents are liquid and ready-to-use • Barcoded cartridges provides on-board management (random placement, on-board stability and calibration tracking) • All 48 R1 and 48 R2 reagent positions are open for third-party reagent use • Auto-calibration and auto-quality control • Automatic changeover from empty to fresh bottle • Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of any size laboratory • Minimal reaction volume of 120 µL reduces reagent consumption • Reagent inventory tracking function predicts daily workloads • Choice of QC trending: Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots • Search function to retrieve data by individual sample and type of test (up to 60,000 patient files) • User-definable flags for abnormal results • Liquid level capacity detection to ensure accurate pipetting for reagents and specimens • Clot detection and crash prevention for probes • Exclusive spot photometric technology for precision optics
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.