Alfa Wassermann Diagnostic Technologies · Model ACE
• Throughput - The ACE system can process up to 165 photometric tests per hour and up to 120 potentiometric (ISE) tests per hour. • Closed Tube Sampling - The ACE system gives you the option of using sample cups or the patented STEP™ module. The STEP (Sample Tube Entry Port) module allows closed tube sampling from primary blood tubes, minimizing the risk of biohazardous exposure. • Smart Sample and Reagent Platform - Real time sample and reagent inventory management tracks sample and reagent lifetime, expiration, number of reagent tests remaining and reagent calibration frequency. • On-Board Sample and Reagent Refrigerated Compartment - The large refrigerated compartment can hold up to 40 test reagents and up to 75 patient samples at any given time. • Auto Repeat and Dilution - Fast, accurate results are ensured as flagged test results are automatically diluted and repeated, without operator intervention. • STAT interrupt - The ACE offers a unique STAT interrupt process for single or panel testing. • On-Board Patient and QC Data Management - The patient data management software can store up to 500 patient records and 2500 requisitions. The QC data management program stores and prints Levy-Jennings Plots for up to 20 controls.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Internal studies observed occasional unexpected outlier results in whole blood samples tested for Hemoglobin A1c using the EZA1c reagent on the ACE or ACE Alera clinical chemistry systems.