Abbott · Model FreeStyle Papillon Mini
Virtually pain free testing, requiring a tiny blood sample to start a test. Allows flexibility to test on alternative sites to rest fingertips. Proven accuracy. Average 7 second test time - so you can get on with life. Back light and test port light - easy to apply the blood sample and check the results in low light. Programmable alarms - 4 daily reminders with an adjustable volume that you can set to suit your lifestyle. Test will only start with a sufficient blood sample. Stores 250 test results with 14 day average - allows review of results quickly and easily.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Result does not fit the clinical picture, poor agreement between duplicate strips, control solution out of range.
Root cause: Damaged, expired or wrong-lot strips, sample too small, or use outside the operating temperature range; haematocrit or interferents.
Symptoms: Error message on the display during or after a test.
Root cause: Faulty or mis-inserted strip, or a meter fault - repeat with a new strip.
Symptoms: Error stating the system is too hot or too cold.
Root cause: Meter and strips outside the specified operating range.
Symptoms: No display on strip insertion, meter will not start a test.
Root cause: Depleted battery or worn / contaminated strip-port contacts.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Single-use; observe the vial expiry and lot.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery | Frequent wear item | $ | Easy |
| Test strips Single-use; observe the vial expiry and lot. | Frequent wear item | $ | Easy |
| Control solution | Frequent wear item | $ | Easy |
| Strip-port contact assembly | Periodic replacement | $$ | Moderate |
| Lancing device | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.