77 Elektronika · Model SensoCard
Advanced biosensor technology. Very small blood sample volume (0.5 µl). Automatic turning on upon strip insertion. Average test time is 5 sec. Memory is enough to store last 500 test data. Built-in 7-14-28 day period average calculation. Long-life, lithium battery. Data downloading capability to PC, via Litelink. Human voice data telling in SensoCard Plus. Easy code setting with code-card. Virtually pain-free.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Result does not fit the clinical picture, large disagreement between duplicate strips, out-of-range control checks.
Root cause: Damaged or mis-inserted test strip, wrong code-card setting, expired strips, or use outside the specified temperature/humidity range.
Symptoms: "E-6" at power-on, meter will not run any more tests after the low-battery icon has been showing.
Root cause: CR2032 batteries depleted - the meter blocks testing 10 measurements after the battery icon first appears.
Symptoms: Nothing happens on strip insertion, test will not start.
Root cause: Worn strip port contacts or a damaged strip.
Symptoms: Erratic reading or reset when used near a mobile phone or microwave oven.
Root cause: Electromagnetic interference or electrostatic discharge.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Single-use consumable; observe the vial expiry.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Test strips Single-use consumable; observe the vial expiry. | Frequent wear item | $ | Easy |
| Strip-port contact assembly | Periodic replacement | $$ | Moderate |
| Control solution / code card | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.