Abbott · Model Cell-Dyne Ruby
MAPSS (Multi-angle, Polarized Scatter Separation) technology to provide accurate optical readings for WBCs with 5-part WBC differential. Cell by cell analysis using hydrodynamic focusing. Accurate WBC enumeration and identification using 4 angles of light scatter on up to 10,000 events per cycle. Multiple scatter plot analysis for identification of abnormal cells and interfering substances. Dual angle optical light scatter accurately enumerates and sizes platelets to reduce manual counts and blood smear reviews. Available full time with no need to repeat the sample in another test mode. Red Blood Cell counts including indices using 3 angles of light scatter, cell sphering and hydrodynamic focusing for accuracy. Uses only 4 reagents including reticulocytes Sampling: Open and Closed Reagents: 3 and Retic Load up Capacity: 50 tubes with 10 per rack Maintenance Requirements: Auto-clean (15 min) daily and manual cleaning of syringes, shear valve, dil/sheath filter weekly
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.