Abbott · Model CELL-DYN 1700
Easy to Operate. Color Display with full Keyboard. Patient name & comments on report. Proven accuracy and reliability. Easy to obtain reagents and controls. 60 CBC’s per hour maximum. 3 Part Differential with counts and percents. WBC, RBC & PLT Histograms on screen and printed on included graphic printer. LIS capability including histograms Only 30uL of sample required. Full computer system with QC, Control Values, Reagent logs, Levy-Jennings charts, Westguard rules, etc. All necessary data for compliance on-line. Comprehensive diagnostic messages. Universal Power 120/240V 50/60Hz. 18-parameter automated system Three-part leukocyte differential Optional closed sampling system Graphical display with three histograms 30 microliter sample requirement 60 seconds for a Complete Blood Count 5,000 specimen data storage with graphics
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.