Abbott · Model Architect C 16000
Equivalent results across all ARCHITECT c Systems Identical technology, reagents and assay protocols Identical software that is intuitive to operate Universal ARCHITECT sample carrier SmartWash technology ensures no clinically significant sample tube to tube carryover (less than 0.1 ppm) Robotic Sample Handler (RSH) eliminates bottlenecks and prioritizes urgent requests Immediate STAT processing for fast and consistent turnaround time Up to 65 refrigerated reagent positions plus patented ISE (Na+, K+, and Cl-) 215 sample load capacity including 35 priority positions Continuous sample access Throughput of up to 1,800 clinical chemistry tests per hour FlexRate methodology extends linearities and avoids repeats Integrated Chip Technology (ICT) delivers ISE (Na+, K+, and Cl-) analysis with minimal maintenance, low sample volume (15 uL), and within run precision of 1% or less Liquid level sensing combined with pressure differential technology for enhanced bubble and clot detection monitors sample integrity.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results, drift over a shift.
Root cause: Reagent or cuvette issue, lamp ageing, a probe / mixer / wash-station fault, or ISE-module problems.
Symptoms: Short aspiration, no dispense, clot detection, probe-position error.
Root cause: Clogged or bent probe, or a clot in the sample.
Symptoms: High cuvette blanks, non-uniform results by position, rotor-drive error.
Root cause: Worn / scratched cuvettes or a wash fault, or a rotor-drive fault.
Symptoms: Electrolyte results biased or noisy, ISE calibration fails.
Root cause: Aged ISE electrodes / reference, or a pinch-valve / tubing fault.
Symptoms: Multiple station alarms, priming failures, poor wash.
Root cause: Water / DI supply quality, a pump, or a vacuum / pressure regulator.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probes | Periodic replacement | $$ | Moderate |
| Photometer lamp | Frequent wear item | $$ | Moderate |
| Reaction cuvettes / segment | Frequent wear item | $$ | Easy |
| ISE electrodes (Na / K / Cl) & reference | Frequent wear item | $$ | Fairly easy |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.