Vital Scientific · Model Selectra XL
• Two rotors each with 24 positions for 25 ml bottles and 8 positions for 5 ml bottles. • All positions can be assigned as R1 and R2. • Adapters for 5 ml bottles in 25 ml positions • Reagent disk compartment is cooled to approx. 12°C below ambient temperature. • Preheated reagent needle with level detection and integrated mixer. • Sample rotor containing • 80 barcode read samples positions • Inner ring for 20 calibrators and 10 controls • STAT and pediatric samples • Continuous loading. • Internal barcode reading • Primary tubes (13 or 16 mm OD) • Sample probe with level detection and integrated mixer. • Semi-disposable rotor with 48 cuvettes. Path length 7 mm. • Minimum measuring volume 220µl. • Measuring temperature 37°C, controlled by Peltier elements • Kinetic measurement with linearity check. • Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction. • Two point measurement. • Graphic plot of all measuring points. • Automatic rerun with sample reduction. • Non-linear calibration curves • Up to 15 different controls can be defined, 3 per test. • Westgard rules. • Levey-Jennings plots.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.