Vital Scientific · Model Flexor Junior
Reagent & Sample system. One rotor combining both sample and reagent positions. Inner rotor ring: -15 positions for reagent bottles -Optionally cooled to approx. 12°C below ambient temperature. Outer rotor ring: - 25 positions for samples, controls and calibrators; - 15 positions for reagent bottles at ambient temperature. All reagent positions can be assigned as R1, R2 and R3. Reagent 1 volume 110 - 400 µl. Reagent 2 volume 0 - 180 µl. Reagent 3 volume 0 - 180 µl. Preheated reagent and sample needle with level detection and integrated mixer. Typical reagent consumption 250 µl per test. Continuous sample loading. 13 mm OD primary tubes. All sample positions can contain 5 ml primary tubes or sample cups. Sample volume 1 - 30 µl per test, programmable in steps of 0.1 µl Analytical modes. Bichromatic end point measurement with or without bichromatic reagent blank and/or sample blank correction. Two point measurement. Graphic plot of all measuring points. Automatic rerun with sample reduction. Non-linear calibration curves Calculation modes. Prozone check for immunology tests. Cut-off declaration. Quality control. Up to 15 different controls can be defined, 3 per test. Westgard rules. Levey-Jennings plots.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results, drift over a shift.
Root cause: Reagent or cuvette issue, lamp ageing, a probe / mixer / wash-station fault, or ISE-module problems.
Symptoms: Short aspiration, no dispense, clot detection, probe-position error.
Root cause: Clogged or bent probe, or a clot in the sample.
Symptoms: High cuvette blanks, non-uniform results by position, rotor-drive error.
Root cause: Worn / scratched cuvettes or a wash fault, or a rotor-drive fault.
Symptoms: Electrolyte results biased or noisy, ISE calibration fails.
Root cause: Aged ISE electrodes / reference, or a pinch-valve / tubing fault.
Symptoms: Multiple station alarms, priming failures, poor wash.
Root cause: Water / DI supply quality, a pump, or a vacuum / pressure regulator.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probes | Periodic replacement | $$ | Moderate |
| Photometer lamp | Frequent wear item | $$ | Moderate |
| Reaction cuvettes / segment | Frequent wear item | $$ | Easy |
| ISE electrodes (Na / K / Cl) & reference | Frequent wear item | $$ | Fairly easy |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.