Varian Medical Systems · Model Truebeam
Yesterday's boundaries are today's starting points. Break the boundaries of today's treatment technologies with a system designed from the ground up to optimize both radiotherapy and radiosurgery. A system that gives oncologists and multidisciplinary teams the power to manage challenging cancers with unparalleled ease and precision anywhere in the body, including the lung, abdomen, breast, head and neck. A radically new solution that is faster, is more powerful and that seamlessly integrates respiratory gating, imaging and treatment techniques. Developed on a sophisticated, synchronized architecture, the system allows users now to navigate the complexities of cancer care with confidence. The TrueBeam system is innovative, intelligent and intuitive.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Beam-on faults, dose-rate low or unstable, RF/HV or arc interlocks.
Root cause: Magnetron/klystron or thyratron at end of life, HV supply, or waveguide arcing / SF6 pressure loss.
Symptoms: Leaf stuck or out of position, delivery interlock, QA fluence errors.
Root cause: MLC leaf motor, leaf-guide wear, or a leaf position-readout fault.
Symptoms: Rotation, field-size or couch position error, position interlock.
Root cause: Drive motor, encoder, or brake.
Symptoms: kV source or flat-panel imaging degraded, poor image for setup, imaging-arm deploy errors.
Root cause: kV X-ray tube, amorphous-silicon panel, or the imaging-arm drive.
Symptoms: Output constancy checks trend out, symmetry/flatness off, chamber interlock.
Root cause: Monitor ion-chamber aging or a dose-servo fault.
Symptoms: Over-temperature interlocks, dose-rate instability, coolant-flow alarm.
Root cause: Chiller pump, heat-exchanger fouling, or low coolant.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
OEM service; dosimetry re-commissioning required.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Magnetron / klystron OEM service; dosimetry re-commissioning required. | Periodic replacement | $$$$ | Expert-level |
| Thyratron | Periodic replacement | $$$$ | Expert-level |
| MLC leaf motor / drive assembly | Major service part | $$$$ | Expert-level |
| kV X-ray tube / a-Si imaging panel | Major service part | $$$$ | Expert-level |
| Monitor ion chamber | Major service part | $$$$ | Expert-level |
| Chiller pump / heat exchanger | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Synced live from the FDA openFDA API.
Reports have been received of an anomaly that can result in a treatment without intended gating (respiratory tracking/monitoring). This issue occurs when a patient planned with gating is treated on more than one system.
Medical device for patient treatment does not meet electrical safety standards.