Elekta · Model Precise Treatment System
Precise Treatment System provides a complete range of service and diagnostic tools to ensure optimal system uptime. Wide choice of energy levels to match treatment needs. Choice of fully integrated MLCi or Beam Modulator. Open system for future expansion. Excellent access for electron and non-coplanar techniques. Elekta Intellimax ready.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Beam-on faults, dose-rate low or unstable, RF/HV or arc interlocks.
Root cause: Magnetron or thyratron at end of life, HV supply, or waveguide arcing / SF6 pressure loss.
Symptoms: Leaf stuck or out of position, delivery interlock, QA fluence errors.
Root cause: MLCi / Agility leaf motor, leaf-guide wear, or a leaf position-readout fault.
Symptoms: Rotation or field-size error, position interlock.
Root cause: Drive motor, encoder, or brake on the gantry or collimator.
Symptoms: Poor or no MV portal image for verification.
Root cause: MV imager panel or its retractable arm.
Symptoms: Output constancy checks trend out, symmetry/flatness off, chamber interlock.
Root cause: Monitor ion-chamber aging or a dose-servo fault.
Symptoms: Over-temperature interlocks, dose-rate instability, coolant-flow alarm.
Root cause: Chiller pump, heat-exchanger fouling, or low coolant.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
OEM service; dosimetry re-commissioning required.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Magnetron OEM service; dosimetry re-commissioning required. | Periodic replacement | $$$$ | Expert-level |
| Thyratron | Periodic replacement | $$$$ | Expert-level |
| MLC leaf motor / drive assembly | Major service part | $$$$ | Expert-level |
| MV portal imager panel | Major service part | $$$$ | Difficult |
| Monitor ion chamber | Major service part | $$$$ | Expert-level |
| Chiller pump / heat exchanger | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.