TRUMPF · Model SATURN Select
Flexible, whatever the requirement. Truly versatile, SATURN Select is ideally suited to everyday surgical work. The tabletop design and longitudinal slide of 250 mm (10) provide ideal access for the C-shaped frame, and optimally support intra-operative diagnoses. SATURN Select is approved for patients weighing up to 225 kg (500 lbs) (Maximum loads may vary depending on the patient´s position and OR table arrangement). A low-height version is available for laparoscopic bariatric surgery. The low and standard height versions are available with the additional options: longitudinal slide and longitudinal slide with integrated body elevator. Optimize and simplify work processes. The robust design of the SATURN Select makes it extremely easy to use. Pneumatic spring support adjustments to the backand leg sections enable the patient to be brought into the required position with minimal effort. The table column uses electro-mechanical motors that provide a high level of performance, precision, safety, and hygiene. Large double-swivel castors make SATURN Select extremely stable and enable it to be moved easily on soft or uneven floors. SATURN Select can be operated intuitively using a remote control. The main table functions are also available from the operating panel on the column.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Height, tilt, Trendelenburg, back or leg section does not respond to the hand control / pendant.
Root cause: Hand control fault, an electro-hydraulic actuator, a control-board fault, or a low battery (mobile column).
Symptoms: Table settles under load after positioning.
Root cause: Hydraulic valve internal leak or an actuator backdrive.
Symptoms: Short run time, table dies mid-procedure, battery alarm.
Root cause: Aged battery pack or a charger fault.
Symptoms: Intermittent or dead hand control.
Root cause: Worn hand control or a damaged cable.
Symptoms: Segments loose, accessory rails will not clamp, pads torn, radiolucent top damaged.
Root cause: Worn segment latches, rail clamps, or upholstery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Electro-hydraulic actuator | Major service part | $$$ | Difficult |
| Hydraulic control valve block | Major service part | $$$ | Difficult |
| Battery pack (mobile column) | Periodic replacement | $$ | Fairly easy |
| Hand control / pendant | Periodic replacement | $$ | Fairly easy |
| Table-top segment pads / rail clamps | Major service part | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Complaints were received of the table top on the transporter (shuttle) tilting down quickly in a maximum Trendelenburg position.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio