MAQUET · Model ALPHASTAR 1132
The mobile operating table ALPHASTAR with electrically controlled hydraulic drive for all the table’s essential functions can be modified to suit the needs of any surgical discipline in just a few quick steps. Intraoperative fluoroscopy There are no crossbars in the operating table, neither in the head plate, back plate, seat plate nor the leg plates, thus enabling intraoperative fluoroscopy. Adjustable in height The flexible height adjustment permits ergonomic and relaxed working positions, both seated and standing. Normal/reverse mode The reverse mode, in which the patient position is reversed 180° head-to-foot, permits additional positioning and surgical possibilities.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Table won't move to commanded position, or moves erratically.
Root cause: Hydraulic pump or electric actuator wear/failure.
Symptoms: Unresponsive or intermittent hand/foot control.
Root cause: Pendant cable, contacts, or wireless receiver wear.
Symptoms: Back, leg, or Trendelenburg section won't lock or articulate.
Root cause: Articulation mechanism or locking pin wear.
Symptoms: Wobble, drift, or difficulty repositioning the table.
Root cause: Caster or locking-wheel mechanism wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Section articulation mechanism | Major service part | $$$ | Moderate |
| Casters / locking wheel set | Major service part | $$ | Fairly easy |
| Hydraulic pump / electric actuator | Major service part | $$$$ | Difficult |
| Control pendant / remote assembly | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →