Teleflex Medical · Model Arrow AutoCAT 2 WAVE® IABP
Speed-of-light AP signal transmission overcomes delays of fluid-filled systems. Reliably anticipates and determines AV closure - before it occurs. 98% timing accuracy within 12 milliseconds (ms) - even during severe arrhythmias. WAVE® Algorithm sets inflation point within the beat, even during arrhythmias. Increases time for coronary perfusion and decreases afterload. AutoPilot™ Mode consistently maintains triggering and timing - Proprietary Best Signal Scoring software brings automaticity to a new level of reliability.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Poor or no diastolic augmentation, abnormal balloon-pressure waveform, gas-loss / leak alarm.
Root cause: Balloon-catheter leak or kink, a loose connection, or low helium.
Symptoms: Pump not triggering or mistimed, inflation / deflation off the cardiac cycle.
Root cause: Poor ECG or arterial-pressure trigger (electrodes, cable, lead selection), or a timing issue.
Symptoms: Autofill fails, cannot maintain balloon volume, drive alarm.
Root cause: Helium cylinder low, a solenoid / compressor fault, or a pneumatic leak.
Symptoms: Short transport battery run time, unresponsive touchscreen.
Root cause: Aged battery packs or a display / control fault.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Helium cylinder | Frequent wear item | $ | Fairly easy |
| Battery packs | Periodic replacement | $$ | Fairly easy |
| Safety chamber / disposable extension tubing | Consumable | $ | Easy |
| Solenoid valve / drive components | Major service part | $$$ | Difficult |
| Touchscreen / control-panel assembly | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
The firm received reports indicating PTD tip separation during use.
Teleflex is initiating a voluntary recall for the above-mentioned products due to reports indicating that the laser guard foil partially separated and/or slightly detached at the edges in the presence of moisture.
The safety cap attached to needles within the needle sets may become dislodged exposing the needle and potentially causing the needle to protrude through the packaging. If this issue is not detected, the immediate risk of exposure to the affected devices is needle stick injury to the clinician or health care professional. In addition, a puncture of the packaging may compromise the sterility of the needle.
Some of the individual unit packaging (pouches) may be missing the lot number an expiration date.
Sterility: Due to a potential incomplete seal on the outer sterile package.