Siemens Healthineers · Model ADVIA Autoslide Slide Maker
Smart Sample User-defined reflexive slide sampling for the right results the first time. •Based on customized ranges, morphology flags and demographics •Aspirates small sample volume of 75 uL only upon decision for slide Smart Smear Classic wedge smear, no sample carryover. •Advancing tape technology •Adjustable smearing profiles •Positive slide identification •150-slide input capacity Smart Stain High-quality, single use reagents for each slide. •Dedicated staining wells •User-definable stain protocols •Stained slides delivered automatically in racks •Accommodates pre-smeared slides Smart Software Flexible user interface. •workstation •Single LIS interface through ADVIA 2120 •Automated maintenance ADVIA 2120 Hematology System with ADVIA Autoslide: Working together to receive rave reviews in your hematology laboratory.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →