Siemens Healthineers · Model ADVIA 2400
Up to 2400 tests/hour (1800 photometric and 600 ISE) Rapid, consistent 2-second cycle time Top-of-class throughput of 200 tubes per hour when running ISEs and up to 9 photometric tests Automatic Sample Retain technology, auto-repeat, auto-dilution and auto-reflex testing Point-in-space aspiration offers connectivity to track or rack handler without robotics or special hardware Redundant sample loading for built-in backup and easy handling of non-routine samples Direct sampling from track prevents detaining tubes at analyzer and reduces aliquotint Minimal-maintenance ISE No-maintenance 37oC incubation fluorocarbon bath oil Auto-calibration and auto-QC from refrigerated on board calibrator and controls Microvolume technology with 32,000 tests onboard and up to 60 days onboard stability maximizes walkaway time Sample integrity check for icterus, hemolysis and lipemia Sample probe with automatic clot/clog detection, liquid level sensing, short sample detection and crash protection Advances in reagent onboard stability, calibration frequency, interference reduction and linearity expansion
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.