Siemens Healthineers · Model ADVIA 2120i
•Save laboratory personnel’s time, improve productivity and reduce costs with practical automation •Results that are right the first time – Quality results for WBC differential, RBC, reticulocyte, PLT and CSF testing •Scalable solution: From standalone to complete automation Save laboratory personnel’s time Only the ADVIA 2120i system gives you Practical Automation - the unique ability to eliminate the majority of manual steps commonly performed for maximum speed and productivity. •Proven technology, reference methods, and onboard delta checks reduce manual slide reviews •Fast, convenient, rack-based sampling: Any tube. Any time. •High throughput of up to 120 samples per hour •Results that are right the first time •Efficient auto-validation procedures Maximize productivity Scalable solutions Expanding your capabilities is easier and more affordable than ever with the ADVIA 2120i system. With integrated and automated solutions from Siemens, you can scale from stand-alone instrument to complete automation as your productivity needs change. •Optional ADVIA® Autoslide Slide Maker Stainer gives you up to 120 high-quality slides per hour to scale up your productivity •Network connectivity via ADVIA CentraLink® Networking Solution allows data management consolidation and QC management from any client workstation •From truly practical automation to complete automation with the same instrument Ease of use The ADVIA 2120i system simplifies and streamlines all aspects of testing, allowing you to work faster and more efficiently so you can focus on other critical tasks. •touch-screen monitor •Unique reagent Time Pacs •Three modes of aspiration: autosampler, open mode, and unique manual closed-tube sampling •Unique Unifluidics technology - reduced fluidics, no pinch valves, automated daily cleaning •Completely automated start-up Quality results - Results that are right the first time The ADVIA 2120i system uses gold-standard peroxidase staining for WBC differential testing. •Fewer reruns •Lowest overall review rate •Faster turnaround time •Lowest linearity - 0.02-400k The system also offers state-of-the-art technology for RBC, reticulocyte, PLT and CSF testing. .RBC •True RBC differential •Consistent morphology •Reduced manuals •Unique dual-hemoglobin measurement capability - eliminates interference from lipemia Automated Reticulocyte Analysis •Direct measurement, not calculated •Excellent in pediatric and dialysis populations PLT •Two dimensions - size and refractive index •Measures up to 60 fl •Includes large platelets in count •Excludes fragments and microcytic RBCs CSF •Results in <5 minutes •Linear to zero with three-part differential •Automated counting provides quality control for consistency .
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable - replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable - replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.