Siemens Healthineers · Model ADVIA 1650
True testing consolidation More than 80 available chemistry and special chemistry methods and applications - plus open channels for user-defined applications - provide cost-effective workstation consolidation. Exceptional performance Advanced, high-precision optical system combines an elongated cuvette path length, our unique incubation fluid and concavity diffraction grating to assure superior performance - exceeding laboratory standards for precision and accuracy in clinical chemistry instrumentation. Proven reliability The average uptime of the ADVIA 1650 is 98%, as proven by our customers - no wonder they cite reliability as their favorite system feature. Microvolume sample technology Minimal sample volume requirements provide sample management efficiency. Microvolume reagent technology - Maximizes on-board capacity and reduces operator interventions. Automation-ready sample probe - Swings 180° away from system to provide direct-track sampling with the ADVIA WorkCell or ADVIA LabCell Modular Automation System. Open-system capability - 100 channels, 62 available for user-defined applications. Innovative optical system - Elongated cuvette path length and fluorocarbon oil incubation bath maximize result accuracy while using microvolume technology for samples and reagents. ADVIA 1650 Universal Rack Handler Automatic rack loading and unloading system ensures unprecedented testing convenience and flexibility. Universal sample racks and carrying trays also retrofit to ADVIA Centaur system.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Controls out of range, calibration fails, flagged results, drift over a shift.
Root cause: Reagent or cuvette issue, lamp aging, a probe / mixer / wash-station fault, or ISE-module problems.
Symptoms: Short aspiration, no dispense, clot detection, probe-position error.
Root cause: Clogged or bent probe, or a clot in the sample.
Symptoms: High cuvette blanks, non-uniform results by position, rotor-drive error.
Root cause: Worn / scratched cuvettes or a wash fault, or a rotor-drive fault.
Symptoms: Electrolyte results biased or noisy, ISE calibration fails.
Root cause: Aged ISE electrodes / reference, or a pinch-valve / tubing fault.
Symptoms: Multiple station alarms, priming failures, poor wash.
Root cause: Water supply / DI quality, a pump, or a vacuum / pressure regulator.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample / reagent probes | Periodic replacement | $$ | Moderate |
| Photometer lamp | Frequent wear item | $$ | Moderate |
| Reaction cuvettes | Frequent wear item | $$ | Easy |
| ISE electrodes (Na / K / Cl) & reference | Frequent wear item | $$ | Fairly easy |
| Peristaltic / pinch-valve tubing | Frequent wear item | $ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.