Schaerer Mayfield · Model Axis 500
Highest capacity for eccentric column table Highest weight capacity of 220kg/485lbs for a cantilevered column table with 1450mm/57" X-Ray window. This means more safety for all kind of patient positions, all kind of operations, all surgical disciplines and a much more stable table. Highest grade stainless steel table Full Stainless steel without rubber cover on the column makes the table ideal from hygienic perspective. Largest X-ray window in the market Due to its very eccentric column design, highest X-ray window in market. No need for sliding! Copied often – never reached! Highest Durability of hand control Hand control design with several functions and LCD screen. Automatic system check show failures for first level service information without delay. Programming features, different language options, adjust “Level” position, additional check for connections. Highest safety features Schaerer AXIS 500-700 is additionally equipped with a second built-in panel controlled an independent circuit. If in an emergency situation the main system fails, the operating table can be controlled with the emergency panel. Highest patient comfort viscoelastic pads are electric conductive, silicon and phthalate-free, 69mm/2,7" high, Velcro free, Ultrasonic welded seams. Easy removable and attachable. Appropriate for long operations and heavy weight patients. Highest flexibility Axis is offered in different variations to fully comply with user’s needs.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Table won't move to commanded position, or moves erratically.
Root cause: Hydraulic pump or electric actuator wear/failure.
Symptoms: Unresponsive or intermittent hand/foot control.
Root cause: Pendant cable, contacts, or wireless receiver wear.
Symptoms: Back, leg, or Trendelenburg section won't lock or articulate.
Root cause: Articulation mechanism or locking pin wear.
Symptoms: Wobble, drift, or difficulty repositioning the table.
Root cause: Caster or locking-wheel mechanism wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Control pendant / remote assembly | Periodic replacement | $$ | Fairly easy |
| Section articulation mechanism | Major service part | $$$ | Moderate |
| Casters / locking wheel set | Major service part | $$ | Fairly easy |
| Hydraulic pump / electric actuator | Major service part | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →