Roche · Model ACCU-CHEK Aviva
Quick, 5-second results. Small 0.6 microliter sample size. Contoured, ergonomic design with easy-to-hold rubber grips. 4 customizable test reminders. Downloadable 500-value memory with 7-, 14- and 30-day averaging. Uses 1 readily available 3-volt lithium coin cell battery. 1,000-test battery life. Compatible with ACCU-CHEK data management tools. Preferred on most healthcare plan formularies, so you may save money5.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Result does not fit the clinical picture, poor duplicate agreement, control solution out of range.
Root cause: Damaged, expired or wrong-lot strips, wrong code chip / key, sample too small, or use outside the operating temperature range.
Symptoms: Error code (E-x) during or after a test.
Root cause: Faulty or mis-inserted strip, or a meter fault - repeat with a new strip.
Symptoms: Error stating the system is too hot or too cold.
Root cause: Meter and strips outside the specified operating range.
Symptoms: No display on strip insertion, meter will not start a test.
Root cause: Depleted battery or worn / contaminated strip-port contacts.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery | Frequent wear item | $ | Easy |
| Test strips and code chip / key | Frequent wear item | $ | Easy |
| Control solution | Frequent wear item | $ | Easy |
| Strip-port contact assembly | Periodic replacement | $$ | Moderate |
| Lancing device | Periodic replacement | $ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
No documents available for this device yet.
Synced live from the FDA openFDA API.
Test strip vials may open while inside sealed cartons during shipment. An open vial might expose the test strips to humidity, which might damage the strips and result in inaccurate results, potentially leading to inappropriate therapy decisions and adverse health consequences.
Inability to dose the test strips, may result in a temporary inability to get a result that could lead to a delay in treatment and/or therapy decisions
The recalling firm identified four US lots of test strips out of specification. Affected strips show increased potential for strip errors prior to applying blood, strips not detected once inserted, or biased results, which may not be detectable. In the case of a biased result, incorrect action could be taken by the user in response to the displayed blood glucose result.
Meters may contain a damaged C29 capacitor resulting in issues with power allegation (short battery life or meter not turning on).
There is a software synchronization issue with the ACCU-CHEK Combo system. In rare cases, when the Manual Pump option is chosen on the ACCU-CHEK Aviva Combo meter, there is a possibility of receiving an incorrect bolus advice recommendation that may cause a temporary under delivery of insulin.
Accu-Chek Aviva Nano Blood Glucose meters that were manufactured for the purpose of validating a manufacturing process for product to be distributed outside the US were distributed in the US through eBay by an unauthorized third party. These meters were not intended for distribution, were not verified to meet final product specifications and were not distributed to customers with the necessary pr
Incorrect patient blood glucose test results may be reported due to a software problem.