Integrated Peripheral Vessel Management packages: The Horizon SE® provides unique cost effective opportunity for hospitals sharing catheterization and Angiography for Angio-shared labs. Integrated Data Management “CIS” Solution: The integrated CIS module provides a centric patient record, collecting data flowing to and from holding, recovery and procedure rooms. This powerful tool enables the utmost convenience for data integration in the cath lab workflow. Integrated Electrophysiology capabilities FDA pending: The Horizon SE’s six integrated intracardiac channels provide a unique, cost-effective opportunity for hospitals that cannot afford a comprehensive EP system. State of the Art Signal Acquisition Module: The CFETM is Mennen’s propriety vital sign monitor type front-end. It is built with cutting edge technology designed to operate under the most strenuous workload conditions of the procedure continuously and flawlessly, minimizing lab downtime to zero.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature or NIBP intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a monitor input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: IBP channel will not zero, offset trace.
Root cause: Pressure input circuit or the transducer cable.
Symptoms: Unresponsive or dim display, missing segments.
Root cause: Display or backlight fault.
Symptoms: Short battery run time, will not hold charge.
Root cause: Aged battery.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Display assembly | Major service part | $$$ | Moderate |
| Battery | Periodic replacement | $$ | Fairly easy |