Laborie Medical · Model Portascan+ Bladder Scanner
Real-time ultrasound scanning and image capture. Simple, intuitive software with touchscreen input. 3.5 - 5.0 MHz abdominal probe for adults and children. Automatic bladder volume calculation. Touchscreen length and width calipers for kidney or other organ measurement. Large database for storage of images, records and reports. Built-in thermal printer for immediate results. Bluetooth® wireless connectivity (with Portaflow™+, Bioscan™+, or PSAwatch™+ reader). On-board touchscreen virtual keyboard for data input. Optional USB input / output. Integrated carry handle and protective screen cover.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No scan on the button press, implausible bladder volume, aiming reticle unstable.
Root cause: Probe / transducer fault, a probe-cable fault, or a calibration issue.
Symptoms: Short run time, will not turn on, will not charge in the cradle.
Root cause: Aged battery or a charging-contact / cradle fault.
Symptoms: Image drops out when the cable is moved, probe not detected.
Root cause: Broken conductors in the probe cable or a worn connector.
Symptoms: Blank or frozen display, touchscreen unresponsive.
Root cause: Display or console-board fault.
Symptoms: No or faint printout.
Root cause: Thermal printer or paper.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Probe / transducer | Periodic replacement | $$$ | Moderate |
| Battery | Periodic replacement | $$ | Easy |
| Probe cable / connector | Periodic replacement | $$ | Fairly easy |
| Display / console board | Major service part | $$$ | Moderate |
| Thermal printer / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
This field correction is being initiated to address potentially damaged seals in the packaging of some the Laborie Pump Tube Sets. Finished goods inventory was detected with damage to their seals in the form of breaches or folds. Based on our investigation the issue appears to be limited to a single lot of part number 902101226 pump tubing sets.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.