Verathon · Model BV1 3000
LCD screen displays bladder position and volume; aiming icon assists in proper probe placement. 3D display shows the bladder in 2 cross-sectional images to verify an accurate scan. Easy-to-print exam results for patient records or reimbursement procedures. Helps document cost savings and catheterizations-prevented based on user-determined statistical input. Anesthesiology Reduce the need for catheterization during surgical procedures. Verify bladder emptiness before anesthesia. Geriatric ward Assess urinary incontinence and retention and the necessity of indwelling catheterization. Neurology Determine the voiding capability of stroke and Spinal Cord Injured (SCI) patients. Pediatric ward Verification of adequate bladder volume prior to suprapubic taps for urine samples. Create feedback for bladder training. Post operative recovery room/ Post operative wards Determine the need to catheterise patients with voiding blockage after anesthesia. Verify catheter blockage versus anuria. Rehabilitation Assess voiding dysfunction. Implementation of Volume versus Time based intermittent catheterization programs. Urology Measure post-void residual (PVR) for the assessment of urinary retention caused by obstruction of the prostate. Verify bladder volume prior to and after uroflowmetry. Uro gynaecology Monitor bladder volume to avoid the risk of over-distention after spinal anesthesia. Verify bladder emptiness prior to pelvic surgical procedures. Post partum assessment of bladder volume prior to catheterization.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: No scan on the button press, implausible bladder volume, aiming reticle unstable.
Root cause: Probe / transducer fault, a probe-cable fault, or a calibration issue.
Symptoms: Short run time, will not turn on, will not charge in the cradle.
Root cause: Aged battery or a charging-contact / cradle fault.
Symptoms: Image drops out when the cable is moved, probe not detected.
Root cause: Broken conductors in the probe cable or a worn connector.
Symptoms: Blank or frozen display, touchscreen unresponsive.
Root cause: Display or console-board fault.
Symptoms: No or faint printout.
Root cause: Thermal printer or paper.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Probe / transducer | Periodic replacement | $$$ | Moderate |
| Battery | Periodic replacement | $$ | Easy |
| Probe cable / connector | Periodic replacement | $$ | Fairly easy |
| Display / console board | Major service part | $$$ | Moderate |
| Thermal printer / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.