Verathon · Model BV1 3000
LCD screen displays bladder position and volume; aiming icon assists in proper probe placement. 3D display shows the bladder in 2 cross-sectional images to verify an accurate scan. Easy-to-print exam results for patient records or reimbursement procedures. Helps document cost savings and catheterizations-prevented based on user-determined statistical input. Anesthesiology Reduce the need for catheterization during surgical procedures. Verify bladder emptiness before anesthesia. Geriatric ward Assess urinary incontinence and retention and the necessity of indwelling catheterization. Neurology Determine the voiding capability of stroke and Spinal Cord Injured (SCI) patients. Pediatric ward Verification of adequate bladder volume prior to suprapubic taps for urine samples. Create feedback for bladder training. Post operative recovery room/ Post operative wards Determine the need to catheterise patients with voiding blockage after anesthesia. Verify catheter blockage versus anuria. Rehabilitation Assess voiding dysfunction. Implementation of Volume versus Time based intermittent catheterization programs. Urology Measure post-void residual (PVR) for the assessment of urinary retention caused by obstruction of the prostate. Verify bladder volume prior to and after uroflowmetry. Uro gynaecology Monitor bladder volume to avoid the risk of over-distention after spinal anesthesia. Verify bladder emptiness prior to pelvic surgical procedures. Post partum assessment of bladder volume prior to catheterization
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Inaccurate volume readings, or no image.
Root cause: Transducer element or cable wear.
Symptoms: Won't hold charge, shuts down mid-scan.
Root cause: Aged rechargeable battery pack.
Symptoms: Scan targets wrong anatomy, inaccurate volume.
Root cause: Internal aiming-icon calibration drift.
Symptoms: Unresponsive controls, frozen screen.
Root cause: Touchscreen digitizer or display aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Core consumable; most-replaced assembly.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Ultrasound transducer / probe head Core consumable; most-replaced assembly. | Periodic replacement | $$$$ | Moderate |
| Rechargeable battery pack | Periodic replacement | $$ | Fairly easy |
| Probe cable | Periodic replacement | $$ | Fairly easy |
| Touchscreen / display module | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →