Eschmann · Model T10 -m
• Powered operating table for general and specialist surgery • 250kg maximum patient weight static, 200kg mobile • Full length radiolucent top with integral x-ray cassette tunnel accessible from either end • 753-1053mm height range with mattresses • 600mm wide table top (across sidebars) - optional width extenders available • Corded handset controlling Trendelenburg, reverse Trendelenburg, lateral tilt, flexion/extension and height • Offset table-top break and offset slimline column for superior imaging and access • Column covers in stainless steel • Battery powered, with facility for connection to mains electricity for immediate use • Low battery warning and battery exhaustion protection • Foot pedal on base to control brakes, wheels and castors for stability, steering and straight-line and 360 degree mobility. Can be accessed from head end or either side of table • Head and leg sections are removable and interchangeable, with an auto-locking mechanism, and can be adjusted with one hand • Covers to the top and base are made of a scratch resistant and colourful acrylic capped ABS mouldings to minimise potential sites for cross contamination and provide a wash down surface to the tabletop • Mattress are moulded and anti-static with no seams so as to remove potential sites on the mattresses where body fluids such as blood can congregate and also to ensure ease of cleaning after each procedure or operation • Special one-piece mattress covering break position (long and short trunk sections) to combat fluid ingress and to provide superior patient support • Standard configuration has 50mm deep mattress, with 75mm mattress option • Optional colour co-ordinated castor covers available • Option of table with divided legs available
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Table won't move to commanded position, or moves erratically.
Root cause: Hydraulic pump or electric actuator wear/failure.
Symptoms: Unresponsive or intermittent hand/foot control.
Root cause: Pendant cable, contacts, or wireless receiver wear.
Symptoms: Back, leg, or Trendelenburg section won't lock or articulate.
Root cause: Articulation mechanism or locking pin wear.
Symptoms: Wobble, drift, or difficulty repositioning the table.
Root cause: Caster or locking-wheel mechanism wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Casters / locking wheel set | Major service part | $$ | Fairly easy |
| Hydraulic pump / electric actuator | Major service part | $$$$ | Difficult |
| Control pendant / remote assembly | Periodic replacement | $$ | Fairly easy |
| Section articulation mechanism | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →