Eschmann · Model T10 -e
• Powered operating table for general and specialist surgery • 250kg maximum patient weight • Full length radiolucent top with integral x-ray cassette tunnel accessible from either end • 703-1053mm height range with mattresses • 600mm wide table top (across sidebars) • Corded handset controlling Trendelenburg, reverse Trendelenburg, lateral tilt, flexion/extension and height • Offset table-top break and offset slimline column for superior imaging and access • Column covers in stainless steel • Battery powered, with facility for connection to mains electricity for immediate use • Low battery warning and battery exhaustion protection • Foot pedals on base to control brakes, wheels and castors for stability, steering and straight-line and 360 degree mobility • Head and leg sections are removable and interchangeable, with an auto-locking mechanism, and can be adjusted with one hand • Covers to the top and base are made of a scratch resistant and colourful acrylic capped ABS mouldings to minimise potential sites for cross contamination and provide a wash down surface to the tabletop • Special one-piece mattress covering break position (long and short trunk sections) to combat fluid ingress and to provide superior patient support • Supplied with 50mm deep mattress
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Table won't move to commanded position, or moves erratically.
Root cause: Hydraulic pump or electric actuator wear/failure.
Symptoms: Unresponsive or intermittent hand/foot control.
Root cause: Pendant cable, contacts, or wireless receiver wear.
Symptoms: Back, leg, or Trendelenburg section won't lock or articulate.
Root cause: Articulation mechanism or locking pin wear.
Symptoms: Wobble, drift, or difficulty repositioning the table.
Root cause: Caster or locking-wheel mechanism wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Control pendant / remote assembly | Periodic replacement | $$ | Fairly easy |
| Section articulation mechanism | Major service part | $$$ | Moderate |
| Casters / locking wheel set | Major service part | $$ | Fairly easy |
| Hydraulic pump / electric actuator | Major service part | $$$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →