Diatron · Model Abacus 3
Color LCD, the large display allows rapid and accurate patient data entry and monitoring of the results with large histogram Sample rotor, ensuring safe and easy sampling The instrument features a sophisticated but easy-to-use, logically constructed multilingual operating menu. It provides 6-level QC, L-J graphs and self-diagnostic functions to let you monitor reliability and accuracy All Abacus models can be interfaced with your host computer for further processing of the measured data. Results can also be retrieved on the built-in roll paper printer Abacus 3 provides 18-parameters, a complete CBC including a 3 part WBC differential High throughput of 60 samples per hour, results within 60 seconds The fluidic system is automatically cleaned from dust particles when turning on the analyzer. High voltage pulses after each measuring cycle keep the apertures free from clogging. The instrument automatically cleans the sampling tip inside and outside after blood aspiration to minimize the risk of carryover and infection. Abacus 3 is almost maintenance free resulting in minimal disruption of operation Clinical environment by utilizing industry standard electronic and mechanic components
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Clogs, high blank, QC fail.
Root cause: Pump tube wear, air in line.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
| Incubator heater / fan | Periodic replacement | $$ | Moderate |
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →