Beckman Coulter · Model LH 755
• Load any sample without presorting or batching with random access testing • Improve testing consistency with automatic reflex slidemaking • Save time and minimize manual intervention with the automated slide preparation module • Increase accuracy and reduce clerical errors with clear slide labeling, stain resistant labels and optional bar coding • Streamline workflow and decrease turnaround time with prioritization of STAT samples • Improve productivity with WBC linearity that extends from zero to 400,000 and platelet linearity that extends from zero to 3,000,000 • Increase clinician confidence at clinical decision thresholds without additional costly testing protocols • Enhance productivity with a reduction in false-positive results and confirmatory tests • Eliminate the use of additional reagents since NRBCs are automatically enumerated with every CBC/diff • Identify and enumerate NRBCs without manual intervention • Improve productivity by reducing the need for technologist intervention and sample re-runs • Standardize laboratory processes across all shifts with user-defined decision rules • Customize the system to meet your lab’s needs and specific patient populations with flexible differential flagging
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Aspiration error, short sample, carryover.
Root cause: Clot/crystal obstruction.
Symptoms: Vibration, loud noise, stop error.
Root cause: Worn bearing or unbalanced rotor.
Symptoms: Incubator out of range.
Root cause: Failed heater/fan or sensor.
Symptoms: Low signal, wavelength drift.
Root cause: Lamp/LED or monochromator aging.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Frequent R&R on high-throughput analyzers.
Consumable, replace proactively.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample aspiration probe Frequent R&R on high-throughput analyzers. | Periodic replacement | $$$ | Moderate |
| Peristaltic pump tubing Consumable, replace proactively. | Frequent wear item | $ | Easy |
| Xenon / LED light source | Periodic replacement | $$$ | Moderate |
| Centrifuge rotor & bearings | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.