Beckman Coulter · Model LH 755
Load any sample without presorting or batching with random access testing. Improve testing consistency with automatic reflex slidemaking. Save time and minimize manual intervention with the automated slide preparation module. Increase accuracy and reduce clerical errors with clear slide labeling, stain resistant labels and optional bar coding. Streamline workflow and decrease turnaround time with prioritization of STAT samples. Improve productivity with WBC linearity that extends from zero to 400,000 and platelet linearity that extends from zero to 3,000,000. Increase clinician confidence at clinical decision thresholds without additional costly testing protocols. Enhance productivity with a reduction in false-positive results and confirmatory tests. Eliminate the use of additional reagents since NRBCs are automatically enumerated with every CBC/diff. Identify and enumerate NRBCs without manual intervention. Improve productivity by reducing the need for technologist intervention and sample re-runs. Standardize laboratory processes across all shifts with user-defined decision rules. Customize the system to meet your lab’s needs and specific patient populations with flexible differential flagging.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Flagged or implausible CBC counts, voteouts, clog alarms, poor precision.
Root cause: Debris or a clot partially blocking a counting aperture or the flow cell.
Symptoms: Short samples, aspiration errors, cap-piercing failures, carryover.
Root cause: Worn or bent sample probe / closed-vial piercer, or a worn shear / segment valve.
Symptoms: WBC, HGB or diff results shifted, high background, reagent alarms.
Root cause: Reagent depleted or wrong lot, or a pinch-valve / tubing fault.
Symptoms: Diff scattergrams abnormal, missing populations, flow-cell or laser alarm.
Root cause: Contaminated or aged flow cell, or the laser / optics.
Symptoms: Multiple parameter errors, priming failures.
Root cause: Pump or regulator drift.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Sample probe / closed-vial piercer | Periodic replacement | $$ | Moderate |
| Shear / segment valve | Periodic replacement | $$$ | Difficult |
| Pinch-valve / peristaltic tubing | Frequent wear item | $ | Moderate |
| Flow cell | Periodic replacement | $$$ | Difficult |
| System reagents / controls | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.