Amico · Model Diagnostic Station
Modular design allows for easy customization Equipment is antimicrobial treated to assist with infection control Rheostat on handle allows easy control of light intensity Handle’s spiral cord expands to over 10 ft (3 m) Compatible with a wide variety of manufacturers’ instrument heads, bulbs and specula Multiple mounting possibilities to suit specific needs.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Otoscope/ophthalmoscope light stays full or off, will not dim from the handle rheostat.
Root cause: Worn rheostat on the handle, a bulb at end of life, or a wall-transformer output fault.
Symptoms: Light flickers or cuts out when the spiral cord is stretched.
Root cause: Broken conductors in the 10 ft coiled cord.
Symptoms: No power to either instrument head.
Root cause: Failed wall transformer or its wiring.
Symptoms: BP gauge reads high or low vs a reference.
Root cause: Wear or shock to the aneroid movement (lifetime calibration warranty).
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Instrument-head bulbs | Periodic replacement | $ | Easy |
| Handle rheostat | Major service part | $$ | Moderate |
| Coiled handle cord | Periodic replacement | $$ | Fairly easy |
| Wall transformer | Major service part | $$ | Moderate |
| Aneroid BP gauge / cuff | Major service part | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.