Toshiba · Model RADREX-i
The power to enhance productivity The Radrex-i is engineered to dramatically improve staff productivity and enhance patient care. Many productivity features are included standard to streamline workflow. The system utilizes two 43 x 43 cm high resolution detectors with high DQE for best image quality at the lowest dose. Radrex-i is the perfect solution to address the challenges with declining reimbursements and increasing patient volumes. Increase power The combination of a high weight capacity table, high heat capacity tube and powerful generator allows you to image larger patients more effectively. Raise productivity Automation comes standard with Radrex-i including features such as auto-tracking, auto-park, auto-collimation, advance image processing and body part mapping. Enhance efficiency A single point-of-contact workstation with easy-to-use ergonomic controls streamlines workflow and accelerates throughput. Improve patient care Tube-side access to examination controls, with an in-room image display, allows point of care decision making to improve patient care. [i]Radrex-i is perfectly adapted to chest, abdomen, extremities and skeletal examinations. In short, Radrex-i extraordinary performance leads the way to the design of all-digital radiography systems. [/i]
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Panel not detected, images not received, wireless / tethered link drops mid-exam.
Root cause: Detector battery (wireless), Wi-Fi / tether cable, a docking / connector fault, or detector electronics.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead pixels / lines, calibration overdue or failing.
Root cause: Detector gain / offset calibration, a bad pixel map, or physical detector (drop) damage.
Symptoms: Exposure inhibited, kV / mAs error, no exposure captured, AEC over/under.
Root cause: HV generator, tube, filament supply, or an AEC / interface fault.
Symptoms: Tube column, wall stand or table bucky will not track, detent, or auto-position.
Root cause: Drive motor, brake, encoder, or the auto-positioning interface.
Symptoms: Images will not display, process or send; worklist missing; slow processing.
Root cause: Workstation PC, software, or the DICOM / network configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Moderate |
| Detector battery (wireless) | Periodic replacement | $$ | Easy |
| Tether cable / access point | Periodic replacement | $$ | Fairly easy |
| Positioner drive / brake / encoder | Major service part | $$$ | Difficult |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
| AEC ion chamber | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
It was discovered during a procedure that when the operator made an exposure on the wireless x-ray detector and the image data was sent to the digital radiography system, and error message was displayed " System Error (2063)" which required a reboot and loss of the image.
It has been found that some of the starter cables used for x-ray tube high speed rotation are not sufficiently durable.
Toshiba America Medical Systems Inc (TAMS) has initiated a field correction on the DRAD-3000E; Radrex-I, Electrostatic x-ray imaging system due to a software bug that results in a loss of image.