Stryker · Model S-Series
Equipment management system. With a redesigned user interface and a compact, fully customizable system, it has never been easier to manage services and maneuver equipment.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Head, knee, height (Hi-Lo) or Trendelenburg will not move from the siderail or caregiver controls.
Root cause: Failed linear actuator, a control-board fault, a capacitive touch-control fault (subject of an S-Series recall), or a pinched / damaged control cable.
Symptoms: Bed will not brake or release, drifts, or the brake pedal / control is unresponsive - the rotational electromagnetic brake is subject of an S-Series recall.
Root cause: Electromagnetic brake actuator, its control, or worn brake linkage.
Symptoms: Bed-exit alarm false-triggers or fails to trigger, weight reads implausibly, will not zero.
Root cause: Load-cell drift or damage, or a scale-control fault.
Symptoms: Bed functions and alarms do not work during a power interruption, battery-fault indicator.
Root cause: Aged back-up battery or a charger fault.
Symptoms: Siderail latch loose, or the integrated control panel unresponsive / cracked.
Root cause: Worn siderail latch or a damaged control panel.
Symptoms: Bed shipped without documented electrical-safety test values.
Root cause: Manufacturing documentation gap - subject of a Stryker recall; perform and document an electrical-safety test before use.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
Recalibrate the scale after replacement.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Linear actuator (head / knee / Hi-Lo) | Major service part | $$$ | Difficult |
| Electromagnetic brake actuator | Major service part | $$$ | Difficult |
| Load cell / scale sensor set Recalibrate the scale after replacement. | Major service part | $$$ | Difficult |
| Back-up battery | Periodic replacement | $$ | Fairly easy |
| Siderail control panel / capacitive touch board | Major service part | $$ | Moderate |
| Control cable / harness | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Patient beds are missing test values for electrical safety tests presenting risk of tissue burn or electrical shock.
The manufacturer has become aware that there is a likelihood that the S-Series Equipment Management System Capacitive Touch Controls on the MFRs rotational electrical magnetic brakes may disengage when an electrocautery device is in use.
During manufacture, packaging materials for a small portion of the lot may not have been properly positioned, resulting in a potential breach in sterility.
The hydraulic jack assemblies (PN: 0753-002-101, 0753-002-070, 0753-002-001, and 0753-002-001) were manufactured using the incorrect oil. The oil used does not contain the same wear resistance additives as the specified oils and therefore its use increases the potential for wear which may cause a leak event or jack drift. Testing was done to evaluate the jacks with incorrect oil and leak events we
Stryker Medical has identified that on some units of the MTA7900, there is a lack of a water temperature display while the unit is in Auto mode. While in Auto mode, only the patient temperature is displayed along with the set point. The water display will be blank during Auto mode. If the user wants to see the water temperature displayed and switches out of Auto mode to Manual mode, then back to
Stryker received a report from the field indicating that a 5.5 mm Cancellous Bone Screw 40 mm was identified in packaging associated with a 6.5 mm Cancellous Bone Screw 25 mm.
Product was packaged with an incorrect packaging material and therefore has a potential to be non-sterile which, if contaminated, could lead to a patient infection.
When users imports more than one image set and changes the viewing direction for both images, the orientation of every other image series might be stored incorrectly, as a mirror image. This may lead to insufficient or inaccurate correlation results or incorrectly shown orientation of every second image series during navigation.
Potential breakage of the internal shaft of the End Cutter Shaver Blade; F-Series, 4.0mm. if breakage occurs, the device becomes non-functional and the defect could be observed through the camera/console system.
Stryker Orthopaedics became aware that there is a potential inability to release the Scorpio Series 7000 Tibial Impactor/Extractor from a tibial baseplate during use.
Rejuvenate Broach system was designed in a manner that may result in the potential for a medical calcar fracture.