Stephanix · Model D2RS 90/90
Column angulation The tube column offers a full angle sweep of +/- 40 °. With tabletop movements, it’s easier to do exams requiring oblique rays, even at the end of the table, without moving the patient. Linear movements The combination of the carriage of the column / detector assembly with the tabletop longitudinal and lateral movements and with the column angulation, offers complete x-ray coverage over the tabletop, whether vertical or horizontal position. Increased access The D2RS 9090 allows tilting of +/- 90 ° , has a variable height from 38 cm(15”) to 148 cm (58”). Accommodating tall users, and offering the lowest height on the market welcoming patients with reduced mobility. Robustness Accessible to challenging or bariatric patients, the table has no movement restrictions up to 230 kg and can support up to 310 kg in horizontal position. The touch control console offers an ergonomic interface combining modernity and aesthetics.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Image noise, artifacts, low SNR.
Root cause: Flat-panel / sensor aging.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
| Workstation RAID / GPU | Periodic replacement | $$$ | Difficult |
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
No documents available for this device yet.
Synced live from the FDA openFDA API.
The firm has detected a potential risk using the command. After releasing the command, the movement of the table may continue instead of stopping.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →