Shaping the future of monitoring for patients [b]XPREZZON[/b] delivers innovative technology and design, to shape the new age of care for clinicians and patients alike. XPREZZON is: [b]Trendy[/b] A high-resolution screen displays crisp and visually rich Custom Trends for faster, better informed patient assessment. With a single touch, clinicians can access different trend views based on observation needs, type of procedure, or clinical protocols. Trends can be displayed continuously on the bedside monitor for real-time updates, or can be sized and arranged as preferred. [b]Enlightened[/b] Highly visible LED alarm lights illuminate, front and back, for increased visual awareness. [b] Expansive[/b] With Spacelabs Dynamic Network Access™ (DNA) the optional dual display allows a dedicated full screen view of physiologic information, plus a secondary screen for charting and other clinical applications. Workstation performance. [b]Versatile[/b] Ergonomic and versatile mounting solutions enhance the overall appearance of the care environment. Various solutions for both monitor and cable management ensure a more organized and efficient workflow at the bedside. [b] Sensitive[/b] XPREZZON is the first patient monitor sensitive to a patient's need for a good night's rest. It intuitively dims the display in low ambient light. [b]Anywhere[/b] Spacelabs' innovative ICS XPREZZ™ provides the ultimate freedom and confidence – patient information on your mobile device – anywhere you have mobile access. [b]Connected[/b] Fully backward compatible, XPREZZON presents a seamless transition between platforms. It also features a highly intuitive touch screen user interface, universal to all Spacelabs patient monitors, to simplify learning and promote the continuity of workflow.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Flat or noisy ECG, frequent lead-off alarms.
Root cause: Worn electrodes, loose leads, or dry gel.
Symptoms: Cuff fails to inflate, erroneous BP, long cycle.
Root cause: Pump/valve wear or cuff leak.
Symptoms: Short backup time, battery alarm on transport.
Root cause: Aged backup battery.
Symptoms: Dim, flickering, or unresponsive screen.
Root cause: Backlight or digitizer failure.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
High-turnover; keep inventory.
Consumable per patient.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| ECG patient cable & lead set High-turnover; keep inventory. | Frequent wear item | $$ | Easy |
| SpO2 sensor (adult/ped/neo) | Frequent wear item | $$ | Easy |
| NIBP cuff & hose Consumable per patient. | Periodic replacement | $ | Easy |
| Rechargeable backup battery | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Potential failure of Spacelabs Healthcare Touchscreen Display, Model 94267 where the alarm lights failed to illuminate upon installation.
There were reports that a certain combination of key presses will cause the module to disconnect from the Xprezzon bedside monitor, model 91393, and the patient parameters will drop from the display. The parameters return after power cycling the monitor.