Spacelabs · Model XPREZZON
Shaping the future of monitoring for patients [b]XPREZZON[/b] delivers innovative technology and design, to shape the new age of care for clinicians and patients alike. XPREZZON is: [b]Trendy[/b] A high-resolution screen displays crisp and visually rich Custom Trends for faster, better informed patient assessment. With a single touch, clinicians can access different trend views based on observation needs, type of procedure, or clinical protocols. Trends can be displayed continuously on the bedside monitor for real-time updates, or can be sized and arranged as preferred. [b]Enlightened[/b] Highly visible LED alarm lights illuminate, front and back, for increased visual awareness. [b] Expansive[/b] With Spacelabs Dynamic Network Access™ (DNA) the optional dual display allows a dedicated full screen view of physiologic information, plus a secondary screen for charting and other clinical applications. Workstation performance. [b]Versatile[/b] Ergonomic and versatile mounting solutions enhance the overall appearance of the care environment. Various solutions for both monitor and cable management ensure a more organized and efficient workflow at the bedside. [b] Sensitive[/b] XPREZZON is the first patient monitor sensitive to a patient's need for a good night's rest. It intuitively dims the display in low ambient light. [b]Anywhere[/b] Spacelabs' innovative ICS XPREZZ™ provides the ultimate freedom and confidence – patient information on your mobile device – anywhere you have mobile access. [b]Connected[/b] Fully backward compatible, XPREZZON presents a seamless transition between platforms. It also features a highly intuitive touch screen user interface, universal to all Spacelabs patient monitors, to simplify learning and promote the continuity of workflow.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: ECG, IBP, SpO2, temperature, CO2 or CO intermittently drops or is implausible.
Root cause: Worn patient cable / sensor, or a parameter-module / input-board fault.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer fault.
Symptoms: The host does not display a plugged-in module or a built-in parameter.
Root cause: Docking / connector fault or an internal board fault.
Symptoms: Blank, dim or distorted display; unresponsive touchscreen.
Root cause: Display, backlight, or controller fault.
Symptoms: Short battery run time, will not hold charge, will not power on.
Root cause: Aged battery pack or a power-supply fault.
Symptoms: Monitor not shown at the central station, admit fails, intermittent drop.
Root cause: Wired / Wi-Fi network configuration or a communication board.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| Parameter module / input board | Major service part | $$$ | Difficult |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Display / touchscreen assembly | Major service part | $$$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
Potential failure of Spacelabs Healthcare Touchscreen Display, Model 94267 where the alarm lights failed to illuminate upon installation.
There were reports that a certain combination of key presses will cause the module to disconnect from the Xprezzon bedside monitor, model 91393, and the patient parameters will drop from the display. The parameters return after power cycling the monitor.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio