Datascope · Model Accutorr Plus
Lightweight, portable design (weighs less than 5 lbs) for easy mobility in preoperative and postoperative areas. Non-invasive blood pressure, SpO2, and pulse rate measurement for comprehensive patient monitoring. Configurable technology allows adjustments for patient size, interval time, alarms, inflation pressure, audio levels, and more.\ Large, easy-to-read display with customizable controls for enhanced usability. Quick-connect, single hose fittings for convenient setup and use. Flexible databases for customizable settings and patient data management. IV pole or bed rail attachment for versatile mounting options. Battery operation ensures mobility and portability in various clinical settings. Stores up to 100 readings, instantly accessible for historical data review. Predictive thermometer module for enhanced temperature monitoring. Printer module for instant documentation and patient record generation. The Datascope Accutorr Plus is an ideal solution for biomedical engineers and healthcare providers seeking a reliable, portable, and easy-to-configure multi-parameter monitor that offers comprehensive patient care with minimal setup time.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: NIBP times out, cuff will not inflate / hold, readings implausible or fail against a reference.
Root cause: Internal NIBP pump or valve, a cuff / hose leak, or a pressure-transducer / calibration fault.
Symptoms: No saturation value or a poor pleth with a good site.
Root cause: Worn SpO2 sensor / cable, or the SpO2 module.
Symptoms: No or implausible temperature.
Root cause: Probe or cable fault.
Symptoms: Short battery run time, will not power on or charge.
Root cause: Aged battery pack.
Symptoms: No or faint strip, paper jam.
Root cause: Thermal print head or paper handling.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient cable set (ECG / IBP / SpO2 / temp) | Frequent wear item | $$ | Easy |
| NIBP cuff and hose | Frequent wear item | $ | Easy |
| Internal NIBP pump / valve | Major service part | $$$ | Difficult |
| SpO2 sensor / cable | Frequent wear item | $$ | Easy |
| Battery pack | Periodic replacement | $$ | Fairly easy |
| Thermal print head / paper | Periodic replacement | $ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
Extracted directly from this unit's own service manual.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Synced live from the FDA openFDA API.
During IAB catheter insertion, the introducer dilator may fracture at the hub, leaving the body of the introducer dilator housed within the sheath. Risks to health include damage to the femoral artery, descending aorta, or embolization; surgical intervention and delay of IAB therapy may also result. Firm has received 10 complaints, including 3 serious adverse events and 1 patient death.
Certain lots containing undersized dilator.
The device was distributed with the outer carton labeled with the manufacture date and the expiry date reversed. This showed the product as expired before it was manufactured.
Maquet/Getinge is initiating a voluntary product removal involving four lot numbers of SENSATION PLUS 8Fr. 50cc Intra-Aortic Balloon Catheter with Insertion Kit & STATLOCK since during internal pressure (leak) testing of the SENSATION PLUS 8Fr. 50cc, IABC, failures related to the tip seal leak were identified.
The Anestar and Anestar Plus Anesthesia System may produce periods of high Positive End-Expiratory Pressure (PEEP), in both manual and mechanical ventilation mode due to an issue with the Applied Pressure Limit (APL) valve.