Shimadzu · Model EZy-Rad Pro
One-Touch Guide -Ensuring stress-free imaging by navigating radiography preparation Optimum setting of the exposure conditions like the exposure distance, cassette size, and grid requirements in accordance with the region to be examined is extremely difficult and requires experience. With EZy-Rad Pro, the wisdom of experienced operators is incorporated in the console. The pre-programmed exposure conditions are displayed on the console for each region, enabling stress-free preparation even for unfamiliar regions. Reference skin dose indicator -- Assisting X-ray dose management In response to the ever increasing demand for lower doses, we have prepared a function that calculates and displays the predicted X-ray dose before exposure based on NDD method (optional). 432 Easy-to-Set Anatomical Programs The compact console is designed to save space while enhancing operator-friendly interface. A standard feature is the productivity-boosting 432 anatomical programs. Entering and changing exposure parameters in these programs is straight-forward and easy. Clear images provide high-quality diagnosis A design based on a 60kHz high-frequency, inverter, X-ray high voltage generator and a 140kHU high-capacity X-ray tube unit allows high-current short-time radiography. This produces sharp images, regardless of patient movement.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Panel not detected, images not received, wireless / tethered link drops mid-exam.
Root cause: Detector battery (wireless), Wi-Fi / tether cable, a docking / connector fault, or detector electronics.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead pixels / lines, calibration overdue or failing.
Root cause: Detector gain / offset calibration, a bad pixel map, or physical detector (drop) damage.
Symptoms: Exposure inhibited, kV / mAs error, no exposure captured, AEC over/under.
Root cause: HV generator, tube, filament supply, or an AEC / interface fault.
Symptoms: Tube column, wall stand or table bucky will not track, detent, or auto-position.
Root cause: Drive motor, brake, encoder, or the auto-positioning interface.
Symptoms: Images will not display, process or send; worklist missing; slow processing.
Root cause: Workstation PC, software, or the DICOM / network configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Moderate |
| Detector battery (wireless) | Periodic replacement | $$ | Easy |
| Tether cable / access point | Periodic replacement | $$ | Fairly easy |
| Positioner drive / brake / encoder | Major service part | $$$ | Difficult |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
| AEC ion chamber | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.