Sedecal · Model X Plus LP +
• Volumetric control depending on the characteristics of the Room in order to avoid possible collisions during the positioning of the system. • Anti-collision pressure sensor during the movement of the system along the Swivel arm. • The Detector Bumper allocated on the bottom of the detector cabinet that when the system is moving down and hits something the system automatically react not only stopping, also goes back up to release the possible pressure make • Emergency Brake allocated on the lateral of the detector Cabinet that enables to fully block the system in case of wrong functioning at any time“Parachute system”, the system has a sensor that is controlling the tension of the steel cable that move the system up and down and if the if is detect any lose of tension, a mechanical block is activate to block the system, avoiding even a complete brake of the steel cable cut Double Photocell system: • One at the Start of the “U” arm area which change automatically the speed of the system to slow motion to not harm the patient when is inside the arm arch. • And close to the end of the “U” arm area, is the second photocell that blocks automatically the system to avoid to harm the patient
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Unexpected shutdown, unit won't power on.
Root cause: PSU or backup battery aging.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or storage degradation.
Symptoms: Images fail to transfer, PACS timeout.
Root cause: Network configuration or interface card fault.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Network interface card | Major service part | $ | Fairly easy |
| Workstation / GPU | Periodic replacement | $$$ | Difficult |
| Power supply unit | Major service part | $$ | Moderate |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →