Quantum · Model QV-800
SKULL PROCEDURES THROUGH LOWER EXTREMITIES, THE QV-800 DOES IT ALL. The exceptional versatility of the QV-800 permits virtually unlimited positioning. Vertical travel of the C-Arm is dual-speed motorized and easily allows for weight bearing exams on children (15” floor-to-focal-spot distance) and skull exams for adults. The system’s main C-Arm rotates 180º, and includes auto stops at 0º, 90º, 135º, and - 45º. The image receptor rotates within a range of +/- 45º to provide for various studies. SAFETY Collision sensors are designed into the electronic movement controls, for both vertical travel and C-Arm positioning. In addition, the receptor unit includes a “collision sensing bumper” designed for additional safety 40”- 72” VARIABLE SOURCE TO IMAGE DISTANCE The QV-800 provides a variable horizontal source-to-image distance (SID) of 40” to 72” (100 – 180 cm) to accommodate a range of radiographic studies. Once the C-Arm is angled into the horizontal position, the x-ray tube assembly can be easily moved from 40” to 72”, by using the operator hand control. POSITIONING FLEXIBILITY AND EASE OF USE The remarkable flexibility of the QV-800 system makes patient positioning and system adjustment quick and easy. The x-ray tube source and the image receptor remain in constant alignment for fast and accurate imaging. The system’s operator-friendly controls, dual speed motorized movements, and collision sensing electronics enable smooth, single-handed operation. 650 POUND PATIENT WEIGHT CAPACITY MOBILE EXAM TABLES WITH FLOATING TOP ADJUSTMENT The QV-800 Universal system simplifies recumbent exams through the use of Quantum’s QT-711-QLW and QT-712-EV Series tables, which can accommodate patients up to 650lbs (295kg).
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Tube won't fire, heat-capacity alarm.
Root cause: Filament wear, cooling failure.
Symptoms: Tube temp alarm, duty-cycle limited.
Root cause: Pump/radiator or coolant loss.
Symptoms: Exposure fails, kV/mA out of range error.
Root cause: HV tank or generator board fault.
Symptoms: Frozen console, acquisition timeout.
Root cause: Workstation or RAID degradation.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Major R&R; track mAs history.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| X-ray tube insert Major R&R; track mAs history. | Major service part | $$$$ | Expert-level |
| Flat-panel detector | Major service part | $$$$ | Expert-level |
| Cooling pump & radiator | Periodic replacement | $$$ | Difficult |
| High-voltage generator | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →