Quantum · Model QV-800
SKULL PROCEDURES THROUGH LOWER EXTREMITIES, THE QV-800 DOES IT ALL. The exceptional versatility of the QV-800 permits virtually unlimited positioning. Vertical travel of the C-Arm is dual-speed motorized and easily allows for weight bearing exams on children (15” floor-to-focal-spot distance) and skull exams for adults. The system’s main C-Arm rotates 180º, and includes auto stops at 0º, 90º, 135º, and - 45º. The image receptor rotates within a range of +/- 45º to provide for various studies. SAFETY Collision sensors are designed into the electronic movement controls, for both vertical travel and C-Arm positioning. In addition, the receptor unit includes a “collision sensing bumper” designed for additional safety 40”- 72” VARIABLE SOURCE TO IMAGE DISTANCE The QV-800 provides a variable horizontal source-to-image distance (SID) of 40” to 72” (100 – 180 cm) to accommodate a range of radiographic studies. Once the C-Arm is angled into the horizontal position, the x-ray tube assembly can be easily moved from 40” to 72”, by using the operator hand control. POSITIONING FLEXIBILITY AND EASE OF USE The remarkable flexibility of the QV-800 system makes patient positioning and system adjustment quick and easy. The x-ray tube source and the image receptor remain in constant alignment for fast and accurate imaging. The system’s operator-friendly controls, dual speed motorized movements, and collision sensing electronics enable smooth, single-handed operation. 650 POUND PATIENT WEIGHT CAPACITY MOBILE EXAM TABLES WITH FLOATING TOP ADJUSTMENT The QV-800 Universal system simplifies recumbent exams through the use of Quantum’s QT-711-QLW and QT-712-EV Series tables, which can accommodate patients up to 650lbs (295kg).
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Panel not detected, images not received, wireless / tethered link drops mid-exam.
Root cause: Detector battery (wireless), Wi-Fi / tether cable, a docking / connector fault, or detector electronics.
Symptoms: Fixed-pattern artefacts, non-uniformity, dead pixels / lines, calibration overdue or failing.
Root cause: Detector gain / offset calibration, a bad pixel map, or physical detector (drop) damage.
Symptoms: Exposure inhibited, kV / mAs error, no exposure captured, AEC over/under.
Root cause: HV generator, tube, filament supply, or an AEC / interface fault.
Symptoms: Tube column, wall stand or table bucky will not track, detent, or auto-position.
Root cause: Drive motor, brake, encoder, or the auto-positioning interface.
Symptoms: Images will not display, process or send; worklist missing; slow processing.
Root cause: Workstation PC, software, or the DICOM / network configuration.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Flat-panel detector (exchange) | Major service part | $$$$ | Moderate |
| Detector battery (wireless) | Periodic replacement | $$ | Easy |
| Tether cable / access point | Periodic replacement | $$ | Fairly easy |
| Positioner drive / brake / encoder | Major service part | $$$ | Difficult |
| Acquisition workstation PC | Major service part | $$$ | Moderate |
| AEC ion chamber | Major service part | $$$ | Difficult |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.