Physio-Control · Model Physio-Control Lifepak 12
Utilizes Physio-Control's ADAPTIV™ biphasic technology to offer you the maximum range of energy settings up to 360 joules Compact and portable Paddle options -- your choice of standard paddles, pediatric paddles, and/or sterilizable internal and external paddles Compatible with QUIK-COMBO® pacing/defibrillation/ECG electrodes (used as a disposable alternative to paddles) Masimo SET® pulse oximetery offers accurate and stable oxygen saturation monitoring Oscillometric noninvasive blood pressure (NIBP) monitoring, with artifact rejection and automatic measurement modes End-tidal CO2 (EtCO2) monitor for both intubated and nonintubated patients, with patented Microstream®, capnography technology and FilterLine® accessories that operate smoothly even in high humidity GE Marquette 12SL™ ECG analysis program provides industry-standard interpretation so you can make treatment decisions with confidence Vital signs trending allows for rapid evaluation of changes in patient condition Cardiac condition and risk are easily tracked. ST-segment deviation is measured every 30 seconds Two channels of invasive pressure monitoring with waveforms and numerics displayed, interfaces with a variety of transducers Bluetooth wireless communication for transmission of 12-lead ECG and patient data.
Compiled for this model from its own documentation and established engineering knowledge for this equipment class - not from a verified service record. Confirm against the manufacturer's service manual.
Symptoms: Delivered energy outside tolerance on the analyser, will not charge, or charges slowly.
Root cause: HV capacitor / charging-circuit ageing, or an output-relay fault.
Symptoms: Short standby, readiness indicator shows service, unit fails the self-test on battery.
Root cause: Aged battery pack or a charging fault.
Symptoms: "Check pads", "connect electrodes", no ECG through pads, poor paceing capture.
Root cause: Worn therapy cable, expired pads, or a paddle / connector fault.
Symptoms: A monitoring parameter drops or is implausible.
Root cause: Patient cable / sensor or the parameter module.
Symptoms: No printout, event data will not transfer.
Root cause: Thermal recorder or the data / Wi-Fi interface.
Serviceable items for this model, compiled from its documentation and engineering knowledge for this equipment class. Service class and relative cost are estimates, not manufacturer figures; no part numbers are given. Confirm intervals and pricing against the manufacturer.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Battery pack | Periodic replacement | $$ | Easy |
| Therapy / defib cable | Periodic replacement | $$ | Fairly easy |
| Multifunction pads | Frequent wear item | $ | Easy |
| HV / charging board | Major service part | $$$$ | Difficult |
| Thermal recorder / print head | Periodic replacement | $$ | Fairly easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A starting sequence for this model, compiled from its documentation and engineering knowledge for this equipment class. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.