Physio-Control · Model LifePak 9P
Micropressor-based unit with optional pacing Operates on either AC Power or Internal Battery Power Sealed lead acid battery back-up Built-in recorder Meet current ACLS standards and has annotating summary Allows for 17 energy selections, HR alarms, 5-lead monitoring, recorder and CODE Summary critical event record Provides: defibrillation, synchronous cardioversion, a Cathode Ray Tube monitor screen, a strip chart recorder, 3-lead electrocardiogram monitoring, heart rate display and alarms, multiple energy selection, and CODE SUMMARY critical event record.
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Charge fails or sluggish, low-energy delivery.
Root cause: Capacitor aging / leakage.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Won't charge or discharges unexpectedly.
Root cause: Relay/contactor wear.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical, keep charged spares.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Charge relay / contactor | Periodic replacement | $$$ | Difficult |
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical, keep charged spares. | Periodic replacement | $$$ | Fairly easy |
| HV energy storage capacitor | Major service part | $$$$ | Expert-level |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.
Ask Bio →