Physio-Control · Model Lifepak 20e
The 20e is highly intuitive to use, making it easy for infrequent AED trained responders to quickly understand and use The closed door reduces the "confusion factor" and ensures basic responders are presented with only the controls they require to facilitate fast and easy operation The proven Shock Advisory System™ from Physio-Control guides users through 1-2-3 step operation, with loud voice prompts and clear, simple graphics cprMAX™ technology provides a resuscitation platform that can increase CPR hands-on time and minimize delays between CPR and shock Clinically advanced and packed with power When the code team arrives, the 20e easily converts to manual mode – with the easy push of a latch the 20e automatically converts to a manual defibrillator For quick and effective clinical decisions, more advanced monitoring parameters such as ECG, external pacing and pulse oximetry are displayed clearly through color-matched waveforms and values MASIMO SET® pulse oximetry offers accurate and stable oxygen saturation monitoring, for quick and effective clinical decisions under conditions of both active movement and low perfusion Lithium-ion battery technology provides extended operating time, making it's easy to transport patients from one area of the hospital to another
Failure patterns typical of this equipment class - general BMET reference, not verified against this exact unit's own service history unless flagged. Severity is a category-level estimate.
Symptoms: Short charge-hold, low-battery on readiness test.
Root cause: Aged battery pack.
Symptoms: No shock delivered, pad error.
Root cause: Worn paddles or expired pads.
Symptoms: Won't charge or discharges unexpectedly.
Root cause: Relay/contactor wear.
Symptoms: Leakage alarm, self-test fail.
Root cause: Failed isolation components.
The parts a BMET typically services on this class of equipment. Service class and relative cost are general engineering estimates for the category, not figures from this unit's documentation. Part numbers appear only when pulled from this unit's own service manual. Always confirm intervals and pricing against the manufacturer.
Critical, keep charged spares.
Expiration-dated consumable.
| Part | Service class | Relative cost | R&R difficulty |
|---|---|---|---|
| Patient interface cable | Periodic replacement | $$ | Fairly easy |
| Rechargeable battery pack Critical, keep charged spares. | Periodic replacement | $$$ | Fairly easy |
| HV energy storage capacitor | Major service part | $$$$ | Expert-level |
| Defibrillation electrodes / pads Expiration-dated consumable. | Consumable | $$ | Easy |
Relative cost: $ lowest · $$$$ highest service-part cost for this equipment class. Not a price.
Preventive-maintenance tasks typical of this equipment class. Perform to the manufacturer's procedure and your facility's policy - this is general reference, not a schedule for this specific unit.
A structured starting point derived from the failure modes above. Follow the manufacturer's service documentation for the actual procedure.
Where this class of equipment is typically deployed - general reference, not this unit's own placement record.
Describe a symptom or error code. Bio answers from this device's own documented error codes, failure modes, parts, and guides.